This is one of N=K=W’s pressure testing
autoclaves. It can test instruments or pressure housings either hot, or
ambient temperature. The samples can be up to 6” [152 mm] in diameter and
21’ [6,4 Mt] long.
Maximum pressure:
30,000 psi [2.000 atm]
Maximum temperature: 550
degF [288 degC]
We also have one autoclave that can test samples up to 4” [100 mm] in diameter and 18” [460 mm] long to a combined environment of 4,000 psi and 754 degF [270 atm and 400 degC]. It covers most of the requirements for testing equipment and seals used in Geothermal exploration.
N=K=W offers this pressure testing service to anyone needing pressure certification for their equipment, or research and development of proprietary components being developed for the down-hole market.